1: Why is voltage boost commonly introduced at low frequencies in V/f control?
15s
To eliminate rotor copper loss
To compensate for the stator resistance voltage drop
To maintain constant mechanical power at zero speed
To increase the number of magnetic poles
2: In a closed-loop V/f drive, the speed controller commonly generates a reference for
15s
DC-link voltage ripple
Slip frequency
Number of stator poles
Carrier-wave amplitude
3: n a closed-loop V/f drive, the load torque suddenly increases and the measured speed falls below its reference. The controller initially responds by:
15s
Reducing the commanded slip frequency to zero
Removing the stator voltage
Increasing the commanded slip frequency to increase torque
Reducing the speed reference automatically
4: Compared with open-loop V/f control, the main benefit of adding speed feedback is:
15s
Improved speed regulation against load disturbances
Independent instantaneous control of flux and torque
Elimination of the need for an inverter
Elimination of rotor slip during torque production
5: In a stable, unsaturated closed-loop V/f drive with a PI speed controller, integral action primarily helps to:
15s
Eliminate all stator-current harmonics
Maintain zero slip at every load
Eliminate steady-state speed error for a constant reference and load
Set the inverter switching frequency
6: If the measured current exceeds the upper hysteresis limit, the controller selects a switching state that:
15s
Increases the current further
Drives the current back toward the hysteresis band
Keeps the existing switching state indefinitely
Sets the current reference to zero
7: Why does conventional fixed-band hysteresis current control generally have a variable switching frequency?
15s
The hysteresis controller changes the motor pole number
The DC-link voltage must reverse polarity every cycle
The current reference must always be a square wave
Current slopes vary with the applied voltage and motor back EMF
8: If the reference current is 8 A and the hysteresis half-band is 0.5 A, the lower and upper current limits are: